ESPHome air sensor: SCD41 + BME688 via BSEC2, API encryption + OTA password
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
This commit is contained in:
71
airsensor-test.yaml
Normal file
71
airsensor-test.yaml
Normal file
@@ -0,0 +1,71 @@
|
||||
esphome:
|
||||
name: airsensor-test
|
||||
|
||||
esp32:
|
||||
board: esp32-s3-devkitc-1
|
||||
variant: esp32s3
|
||||
framework:
|
||||
type: esp-idf
|
||||
|
||||
wifi:
|
||||
ssid: !secret wifi_ssid
|
||||
password: !secret wifi_password
|
||||
fast_connect: true
|
||||
reboot_timeout: 0s
|
||||
|
||||
logger:
|
||||
hardware_uart: UART0
|
||||
|
||||
api:
|
||||
encryption:
|
||||
key: !secret api_encryption_key
|
||||
reboot_timeout: 0s
|
||||
|
||||
ota:
|
||||
- platform: esphome
|
||||
password: !secret ota_password
|
||||
|
||||
i2c:
|
||||
sda: GPIO8
|
||||
scl: GPIO9
|
||||
scan: true
|
||||
|
||||
# BME688 via Bosch BSEC2 (IAQ / bVOC) — replaces the raw bme680 platform.
|
||||
# BSEC is Bosch closed-source; compiling it accepts their license.
|
||||
# state_save_interval keeps the learned gas baseline across reboots.
|
||||
bme68x_bsec2_i2c:
|
||||
address: 0x76
|
||||
model: bme688
|
||||
operating_age: 28d
|
||||
sample_rate: LP
|
||||
supply_voltage: 3.3V
|
||||
state_save_interval: 6h
|
||||
|
||||
sensor:
|
||||
- platform: scd4x
|
||||
co2:
|
||||
name: "SCD41 CO2"
|
||||
temperature:
|
||||
name: "SCD41 Temperature"
|
||||
humidity:
|
||||
name: "SCD41 Humidity"
|
||||
|
||||
- platform: bme68x_bsec2
|
||||
# eCO2 intentionally omitted — real CO2 comes from the SCD41.
|
||||
temperature:
|
||||
name: "BME688 Temperature"
|
||||
pressure:
|
||||
name: "BME688 Pressure"
|
||||
humidity:
|
||||
name: "BME688 Humidity"
|
||||
gas_resistance:
|
||||
name: "BME688 Gas Resistance"
|
||||
iaq:
|
||||
name: "BME688 IAQ"
|
||||
breath_voc_equivalent:
|
||||
name: "BME688 bVOC"
|
||||
|
||||
text_sensor:
|
||||
- platform: bme68x_bsec2
|
||||
iaq_accuracy:
|
||||
name: "BME688 IAQ Accuracy"
|
||||
Reference in New Issue